Jinsheng Mist Forest-High Pressure Mist System is one of the leading manufacturers and suppliers of precision humidification unit in China. If you're going to wholesale cheap precision humidification unit made in China, welcome to get free sample from our factory. All customized products are with high quality and low price.
The Precision Humidification Unit is a packaged high-pressure misting system for controlled humidity adjustment in industrial environments. Filtered water is pressurized to 50–70 bar and delivered through stainless steel piping to fine-atomizing nozzles. Typical droplets are approximately 5–15 μm, providing fine moisture distribution where air temperature, airflow, and relative humidity support evaporation.
The unit is used in production workshops, warehouses, processing areas, greenhouses, and other controlled environments. Pump flow, nozzle quantity, motor capacity, and piping configuration are selected from the required moisture load and site conditions.
How the Unit Works
Water Filtration: Incoming water passes through filtration before entering the high-pressure circuit. Filtration requirements are established from the incoming water condition and the specifications of the installed nozzles.
High-Pressure Delivery: The pump raises filtered water pressure to the typical 50–70 bar operating range. Pump flow is matched to the total flow required by the active nozzle network.
Fine Atomization: Pressurized water passes through fine-atomizing nozzles and forms droplets typically measuring 5–15 μm. Moisture distribution and evaporation depend on temperature, airflow, relative humidity, and the distance available for evaporation.
Key Specifications
|
Parameter |
Typical Specification |
|
Product Type |
Precision industrial humidification unit |
|
Operating Pressure |
50–70 bar |
|
Typical Droplet Size |
5–15 μm |
|
Water Supply |
Filtered water |
|
Piping Material |
Stainless steel |
|
Atomization Method |
High-pressure fine mist |
|
Pump Flow |
Selected according to nozzle demand |
|
Nozzle Quantity |
Selected according to humidification load |
|
Motor Capacity |
Selected according to pump requirements |
|
Control Configuration |
Application-dependent |
Final equipment data is established from the required humidification load, water conditions, installation layout, and available electrical supply.
Application Areas
Production Workshops
Used in manufacturing areas where relative humidity forms part of the production environment. Nozzle placement and water output are matched to the room dimensions, airflow, and required operating zones.
Warehouses
Applied to storage environments requiring controlled moisture addition. Separate active zones can be arranged according to the storage layout and operating requirements.
Processing Areas
Used where humidity is part of the process environment. System capacity is determined from process conditions, moisture demand, ventilation, and operating schedule.
Greenhouses
Fine mist can be used for humidity adjustment where air movement, temperature, and evaporation conditions support effective moisture distribution.
Selection Factors
Humidity Requirement: Define the current relative humidity, target humidity range, ambient temperature, and operating period. These values establish the starting point for calculating the required moisture addition.
Space and Airflow: Room length, width, height, ventilation rate, air movement, heat sources, and air exchange affect moisture distribution and evaporation.
Water Conditions: Incoming water should be evaluated before equipment selection. Water quality determines the required filtration arrangement and can influence nozzle selection and maintenance requirements.
Installation Layout: Nozzle height, spacing, piping length, active zones, equipment location, service access, drainage, and electrical supply should be confirmed during system planning.
Configuration Options
Pump and Flow
Pump capacity is selected according to operating pressure and total nozzle flow. The pump must provide sufficient flow for the number of nozzles operating within each active zone.
Nozzle Arrangement
Nozzle quantity and spacing are determined from humidification demand, installation height, airflow, and room geometry. The layout is established from the actual application rather than a fixed nozzle count.
Control Method
Control configuration can be matched to the required operating sequence. Zone-based operation and humidity-responsive operation can be incorporated when specified by the project.
Piping System
Stainless steel high-pressure piping connects the pump unit with the atomizing nozzles. Pipe sizing is selected according to operating pressure, flow demand, piping length, and system layout.
Installation Requirements
Water Supply
A stable filtered water supply is required. Water conditions should be reviewed before commissioning so the filtration arrangement corresponds to the selected system configuration.
Air Movement
Air movement affects moisture dispersion and evaporation. Nozzle positions should be coordinated with ventilation patterns and the direction of air movement within the space.
Electrical Supply
Motor capacity and electrical configuration are selected according to pump requirements and the available site power supply.
Service Access
Clear access should be maintained around filtration components, pump assemblies, pressure connections, and nozzles for inspection, adjustment, and routine service.
Quality and Production Considerations
Component Control: The main assembly includes the high-pressure pump, filtration components, pressure-control components, stainless steel piping, and atomizing nozzles. Component specifications are matched to the required pressure and flow range.
Assembly Inspection: Piping connections, pressure joints, nozzle installation, filtration components, and operating parameters are checked during assembly and system inspection.
Documentation: Technical documentation can include equipment specifications, operating parameters, component data, piping information, installation requirements, and inspection records for project review and equipment acceptance.
How to Specify the Unit
Provide the following information when requesting a system configuration:
Room length, width, and height
Current relative humidity
Target relative humidity
Ambient temperature
Ventilation and airflow conditions
Required operating hours
Water supply and water quality
Available electrical supply
Installation height and equipment location
Required humidification zones
These details provide the basis for selecting pump flow, nozzle quantity, piping arrangement, motor capacity, and overall unit configuration.
FAQ
Q: What is the typical operating pressure?
A: The typical operating range is 50–70 bar. Final pressure depends on the selected pump, nozzle configuration, and required water flow.
Q: What droplet size does the unit produce?
A: Typical droplets are approximately 5–15 μm. Actual droplet characteristics vary with operating pressure, nozzle specification, water conditions, and surrounding air conditions.
Q: How is humidification capacity determined?
A: Capacity is determined from target humidity, room volume, temperature, ventilation, airflow, moisture load, and operating time. Floor area alone does not define the required system output.
Q: What water quality is required?
A: Filtered water is required. The filtration arrangement is selected according to incoming water quality and the requirements of the installed atomizing nozzles.
Q: Can different areas operate independently?
A: Yes. The system can be divided into separate humidification zones when independent operation is required. Pump flow and nozzle quantity are selected according to the active zones.
Q: What information is needed for a quotation?
A: Provide room dimensions, current and target humidity, ambient temperature, airflow conditions, water supply, electrical supply, operating schedule, installation height, and preferred equipment location. This information supports accurate system sizing and configuration.
Hot Tags: precision humidification unit, China precision humidification unit manufacturers, suppliers, factory, mosquito misting system kit, Outdoor Misting Fan, pond fogger, ultrasonic mister fogger, wall mount misting fan outdoor, water mist dust suppression system